Debromination and Bromination of Cholesterol

Bromination/debromination which is an important organic reaction that aims in purification of crude cholesterol from impurities which include 3-cholestanol, 7-cholesten-3-ol, and 5,7-chlestadien-3-ol was performed in a laboratory scale for two weeks. Due to steric constraints, only cholesterol reacted with bromine and crystallized from the solution making it possible to be separated (Feiser, and Williamson 63). The dibromocholesterol formed is regenerated by reacting with Zinc dust. In addition, three methods were used to evaluate the effectiveness. These were Sodium Iodide test, Silver Nitrate test, and Sulfuric acid test. NaI test showed a positive response as color changed to yellow. The formation of the precipitate also indicated a positive result. The sodium iodide reagent reacted with 1° and 2° alkyl halides through an SN2 mechanism. On the other hand, the silver nitrate reagent reacted with 2° and 3° alkyl halides through an SN1 mechanism.  Negative results were observed for both the commercial cholesterol and 1-chlorobutane (Zubrick 38). Conversely, the t-butyl chloride gave a positive result for the AgNO3 test and a negative result for the NaI test. The synthesized cholesterol was 0.29 gram and the theoretical yield was 1.08 gram. This gave a percent yield of 26.9 gram. Although this was a low yield the TLC analysis confirmed a high purity of the synthesized cholesterol. The melting point of the synthesized cholesterol and commercial cholesterol seems to fall in the same range. This confirms the purity of the synthesized cholesterol. TLC analysis was carried out to confirm the purity of the analysis. The distance traveled by commercial cholesterol was 5.5 whereas that travelled by the synthesized cholesterol was 4.6. The absence of other spots on the TLC plate confirms that there were no contaminations present in the sample.

Don't use plagiarized sources. Get Your Custom Essay on
Debromination and Bromination of Cholesterol
Just from $13/Page
Order Essay

Get Help With Your Essay
If you need assistance with writing your essay, our professional essay writing service is here to help!
Essay Writing Service

Introduction
Cholesterol is an important steroidal compound found in both animals and plants. Despite the fact that cholesterol causes diseases, it plays a vital role in life. For example, cholesterol is the main structural component in cell walls and in myelin sheath formation. It is also a major precursor for most steroid hormones. Crude cholesterol is isolated from natural sources and various methods have been used in its purification. Crude cholesterol contains approximately 3-5% contamination. Some of the contaminants are 3-cholestanol, 7-cholesten-3-ol, and 5,7-chlestadien-3-ol shown below.
Some common contaminants of commercial cholesterol The main objective of this experiment was to purify commercial cholesterol using organic reaction chemistry, including the use of the electrophilic addition. For complete purification of cholesterol from the above impurities is achieved by a reaction of bromine with cholesterol to generate dibromocholesterol. Because of the steroid ring structure present in these compounds that causes steric constraints, only cholesterol reacts with bromine to form an insoluble diaxial dibromo compound through electrophilic addition. On the other hand, cholestanal does not react with bromine and the other two contaminants are dehydrogenated by bromine leading to formation of soluble dienes and trienes respectively. The dibromo-cholesterol precipitates as a solid leaving the other impurities in the reaction solvent. A purification step such as solvent washing or crystallization is carried out to separate the solid from the impurities. The solid dibromo-cholesterol is then reacted with zinc in order to regenerate pure cholesterol.
Reaction Scheme for the Bromination/Debromination of Cholesterol
To test the effectiveness of this reaction three different chemical tests namely sodium iodide in acetone, silver nitrate in ethanol test, and sulfuric acid test, were performed. Each of these tests is selective for a specific functional group. Dibromocholesterol contains both primary and secondary alkyl halides and reacts with a sodium iodide in acetone and silver nitrate in ethanol to form a precipitate or a cloudy solution. In addition, the presence of double bonds in dibromocholesterol in form of alkene makes it possible for the formation of a fluorescent green sulfuric acid layer and a red chloroform layer when reacted with sulfuric acid (Landgrebe 78).
Material and Methods
1g of commercial cholesterol was added to a 25 mL Erlenmeyer flask. 7 mL t-butylmethyl ether was measured with a graduated cylinder and added to the flask containing the cholesterol and a magnetic stir bar. A water bath was then set up on the hotplate in the hood. The Erlenmeyer flask contain the reaction solution was inserted into the water bath and clamped as shown below. The heat and the stirrer were turned on and gently heat until all the cholesterol dissolved in t-butylmethyl ether.
The flask was removed from the water bath after all the cholesterol was completely dissolved and allowed to cool to room temperature. After the cholesterol solution was cooled, the flask was clamped to the ring on the hot plate as shown in figure 4 and stirred without heating. A burette was then used to dispense 5 mL of bromine solution into the flask. A precipitate solution formed almost immediately.
The water bath was replaced with ice and tap water and the reaction solution stirred intermittently with a glass stir rod for ~ 10 minutes to complete the crystallization of the product. About 20 mL of the t-butylmethyl ether – acetic acid solution was then dispensed in a clean 50 mL Erlenmeyer flask which was clamped to a ring stand and allowed to cool in the ice bath. A vacuum filtration was done using a Buchner funnel and filter paper. The solid in the filter was washed using ~10 mL of the cooled solution of t-butylmethyl ether – acetic acid and then with ~10 ml of methanol. The solid was then allowed to dry with the vacuum on for about 5 minutes. the dibromocholesterol melting point was measured and recorded. The dry solid was weighted and sealed in a vial and stored for next experiment. To debrominate cholesterol, 20 mL of t-butylmethyl ether, 5 mL of acetic acid and 0.2 g of Zn dust were added into the Erlenmeyer flask containing the dibromocholesterol solid. The mixture was swirled for 5-10 minutes in the hood and sonicated in 5 minutes to allow the reaction to go completion. After sonication the solids present were removed by gravity filtration method into a clean 125 mL Erlenmeyer flask. The filtrate was transferred to a 125 mL separatory funnel in which 20 mL of deionized water was added, shaken and allowed to separate into layers. The two layers formed were then separated as water layers and organic (ether) layers. The ether layer was washed with 20 mL of 10% NaOH and then 20 mL of saturated NaCl solution. 100mg of the drying agent magnesium sulfate was added to the organic layer and the solution swirled until dry. The drying agent was removed by gravity filtration using a glass funnel fluted filter paper and a very dry 50 mL Erlenmeyer flask. The flask was placed in a warm water bath and then ice cooled for 10 minutes until all but 5 mL of the ether remained following a precipitate formation from the solution. The remaining solvent was decanted and the synthesized cholesterol transferred and allowed to dry in the hood for 20 minutes.The dry solid was weighed and the weight recorded. In addition the melting point was also taken and recorded. To evaluate the effectiveness of the bromination reaction three chemical reactions mentioned above were carried out. NaI in acetone test Five test tubes labeled A, B, C, D and E were used for this test.  About 30 mg of the commercial cholesterol starting material was added to tube A; ~30 mg of dibromocholesterol to tube B; ~30 mg of the synthesized cholesterol product to tube C; ~0.3 mL of 1-chlorobutane to tube D; and ~ 0.3 mL of t-butyl chloride to tube E.  In addition, about 3 mL of acetone was added to each tube to completely dissolve all the compounds.  Solutions A-E was used to do the NaI in acetone test as well as the AgNO3 in ethanol test. Tubes A-C did the TLC as well. The NaI in Acetone and AgNO3 in Ethanol tests were performed by setting up a test tube rack containing ten small test tubes. The test tubes were labeled N1 – N5 and A1 – A5. 1 mL of NaI in acetone reagent was added to test tubes N1 – N5, and 1 mL of AgNO3 in ethanol reagent to test tubes A1 – A5. This was followed by adding 5-8 drops of A solution to test tube N1 and tube A1, 5-8 drops of solution B to test tube N2 and tube A2, 5-8 drops of solution C to to test tube N3 and tube A3, 5-8 drops of solution C to test tube N4 and tube A4, and 5-8 drops of solution C to test tube N5 and tube A5. The test tubes were heated for a while and all the observations recorded. The sulfuric acid for alkenes test was performed by additional solutions of cholesterol and dibromocholesterol with five dry-cleaned test tubes 1-5. 10 mg of commercial cholesterol was placed in tube 1, ~10mg of the dibromocholesterol to tube 2 ~10 mg of your synthesized cholesterol to tube 3, ~10 mg of 2-chlorobutane to tube 4, and 10 mg of cyclohexene to tube 5. About 1 mL of chloroform (CHCl3) was added to each tube and vortex to completely dissolve all solids.  In addition, 0.5 mL of H2SO4 was then added to each tube. The observation for this reaction was recorded in the notebook. The TLC analysis of cholesterol and dibromocholesterol was performed by obtaining a silica gel TLC plate and setting it up to run TLC analysis on solutions A-C above. The plate was spotted with each solution and developed by placing the plate using 30% ethyl acetate: 70% hexane as the mobile phase. The developed plates were viewed under UV lamp and in the I2 chamber and observations recorded.
Discussion
The yield of the synthesized cholesterol was .29 grams (Table 1). The theoretical yield was 1.08 grams. The actual yield was calculated by taking the difference of the weight of the round bottom flask and the synthesized cholesterol by the synthesized cholesterol’s weight alone. The percent yield was calculated to be 26.9 percent. The synthesize process was not efficient due to the low yield and percent yield of the synthesized cholesterol.
The melting point of the synthesized cholesterol and commercial cholesterol seems to fall in the same range. This confirms the purity of the synthesized cholesterol. NaI test showed a positive response as color changed to yellow. The formation of the precipitate also indicated a positive result. The sodium iodide reagent reacted with 1° and 2° alkyl halides through an SN2 mechanism. On the other hand, the silver nitrate reagent reacted with 2o and 3° alkyl halides through an SN1 mechanism.  Negative results were observed for both the commercial cholesterol and 1-chlorobutane. Conversely, the t-butyl chloride gave a positive result for the AgNO3 test and a negative result for the NaI test. The stationary phase of the TLC test was the silica gel TLC plate and the mobile phase was 30% Ethyl Acetate/70% Hexane (Table 6). The distance traveled by commercial cholesterol was 5.5, and for the synthesized cholesterol was 4.6. The difference in the distance traveled and the Rf values of the samples commercial and synthesized cholesterol were pure. Since there were no other spots visible on the TLC plate was a clear indication that there were no contaminations of other chemical compounds present in the sample.
 

What Will You Get?

We provide professional writing services to help you score straight A’s by submitting custom written assignments that mirror your guidelines.

Premium Quality

Get result-oriented writing and never worry about grades anymore. We follow the highest quality standards to make sure that you get perfect assignments.

Experienced Writers

Our writers have experience in dealing with papers of every educational level. You can surely rely on the expertise of our qualified professionals.

On-Time Delivery

Your deadline is our threshold for success and we take it very seriously. We make sure you receive your papers before your predefined time.

24/7 Customer Support

Someone from our customer support team is always here to respond to your questions. So, hit us up if you have got any ambiguity or concern.

Complete Confidentiality

Sit back and relax while we help you out with writing your papers. We have an ultimate policy for keeping your personal and order-related details a secret.

Authentic Sources

We assure you that your document will be thoroughly checked for plagiarism and grammatical errors as we use highly authentic and licit sources.

Moneyback Guarantee

Still reluctant about placing an order? Our 100% Moneyback Guarantee backs you up on rare occasions where you aren’t satisfied with the writing.

Order Tracking

You don’t have to wait for an update for hours; you can track the progress of your order any time you want. We share the status after each step.

image

Areas of Expertise

Although you can leverage our expertise for any writing task, we have a knack for creating flawless papers for the following document types.

Areas of Expertise

Although you can leverage our expertise for any writing task, we have a knack for creating flawless papers for the following document types.

image

Trusted Partner of 9650+ Students for Writing

From brainstorming your paper's outline to perfecting its grammar, we perform every step carefully to make your paper worthy of A grade.

Preferred Writer

Hire your preferred writer anytime. Simply specify if you want your preferred expert to write your paper and we’ll make that happen.

Grammar Check Report

Get an elaborate and authentic grammar check report with your work to have the grammar goodness sealed in your document.

One Page Summary

You can purchase this feature if you want our writers to sum up your paper in the form of a concise and well-articulated summary.

Plagiarism Report

You don’t have to worry about plagiarism anymore. Get a plagiarism report to certify the uniqueness of your work.

Free Features $66FREE

  • Most Qualified Writer $10FREE
  • Plagiarism Scan Report $10FREE
  • Unlimited Revisions $08FREE
  • Paper Formatting $05FREE
  • Cover Page $05FREE
  • Referencing & Bibliography $10FREE
  • Dedicated User Area $08FREE
  • 24/7 Order Tracking $05FREE
  • Periodic Email Alerts $05FREE
image

Our Services

Join us for the best experience while seeking writing assistance in your college life. A good grade is all you need to boost up your academic excellence and we are all about it.

  • On-time Delivery
  • 24/7 Order Tracking
  • Access to Authentic Sources
Academic Writing

We create perfect papers according to the guidelines.

Professional Editing

We seamlessly edit out errors from your papers.

Thorough Proofreading

We thoroughly read your final draft to identify errors.

image

Delegate Your Challenging Writing Tasks to Experienced Professionals

Work with ultimate peace of mind because we ensure that your academic work is our responsibility and your grades are a top concern for us!

Check Out Our Sample Work

Dedication. Quality. Commitment. Punctuality

Categories
All samples
Essay (any type)
Essay (any type)
The Value of a Nursing Degree
Undergrad. (yrs 3-4)
Nursing
2
View this sample

It May Not Be Much, but It’s Honest Work!

Here is what we have achieved so far. These numbers are evidence that we go the extra mile to make your college journey successful.

0+

Happy Clients

0+

Words Written This Week

0+

Ongoing Orders

0%

Customer Satisfaction Rate
image

Process as Fine as Brewed Coffee

We have the most intuitive and minimalistic process so that you can easily place an order. Just follow a few steps to unlock success.

See How We Helped 9000+ Students Achieve Success

image

We Analyze Your Problem and Offer Customized Writing

We understand your guidelines first before delivering any writing service. You can discuss your writing needs and we will have them evaluated by our dedicated team.

  • Clear elicitation of your requirements.
  • Customized writing as per your needs.

We Mirror Your Guidelines to Deliver Quality Services

We write your papers in a standardized way. We complete your work in such a way that it turns out to be a perfect description of your guidelines.

  • Proactive analysis of your writing.
  • Active communication to understand requirements.
image
image

We Handle Your Writing Tasks to Ensure Excellent Grades

We promise you excellent grades and academic excellence that you always longed for. Our writers stay in touch with you via email.

  • Thorough research and analysis for every order.
  • Deliverance of reliable writing service to improve your grades.
Place an Order Start Chat Now
image

Order your essay today and save 30% with the discount code Happy